Bridging worlds · Powering up Pakistan

When the unit comes off load,
the clock is ours.

Gohar Energy Services delivers power plant operations and maintenance, planned outages, major overhauls, long-term service agreements, spare parts and component refurbishment across Pakistan — bringing international OEM-grade capability to plant owners at a competitive cost.

58 GW Generation capacity under maintenance and O&M across our principal network
34 Countries of overseas maintenance delivery, continuously since 1982
13 Overhauls, inspections and technical assignments already delivered on Pakistani plant
5,935 Engineers and field specialists in the principal network we mobilise from

Core business · Power sector O&M

Six services. One accountable contract holder.

Everything else we do supports the power sector work. GES keeps rotating and static plant available, efficient and safe — from a single vibration call-out to full-scope O&M of a combined cycle block under a multi-year agreement.

01

Operation & maintenance

Full-scope, partial-scope or supervisory O&M for thermal, combined cycle and renewable plants. Resident teams, planned maintenance regimes, spares management, statutory inspections and availability reporting against contracted KPIs.

02

Long-term service agreements

Multi-year LTSAs structured, tendered and delivered with our principals: scheduled outage cover, parts supply and pooling, component refurbishment, resident technical support and remote monitoring — priced against plant running hours, not list price.

03

Outages & major overhauls

Planned and forced outage execution on gas turbines, steam turbines, generators, HRSGs, boilers and balance of plant. Combustion inspections, hot gas path inspections, major inspections, minor and major overhauls — scoped, mobilised and closed out on schedule.

04

Spare parts & tooling

OEM and non-OEM spares, sub-assemblies, consumables, specialist tooling and rental equipment — including reverse-engineered replacement parts. Sourcing, import, clearance through the Pakistan Single Window, warehousing and site delivery timed to the outage window.

05

Repair & refurbishment

Life extension and reconditioning of hot gas path components, rotor assemblies, blades and vanes, generator windings, protective coatings, heat exchangers and valves — in Pakistan where possible, or through accredited international workshops with full documentation.

06

Engineering & diagnostics

Condition and residual life assessment, root cause analysis, vibration and noise analysis, performance and efficiency testing, retrofit and rehabilitation studies, technical evaluation of contractors and bids, commissioning support, alignment and balancing.

Inside the overhaul

What our teams actually do on the floor

Scopes are written in equipment terms, not marketing terms. Below is the work our principals’ crews and our local teams execute inside a typical outage window. Replace each tile below with your own site photographs.

Add photo
(tile-1.jpg)

Rotor lifted, blade path exposed

Diaphragm inspection, blade NDT, clearance recording, balancing and re-assembly to OEM tolerances.

Add photo
(tile-2.jpg)

Gas turbine major inspection

Combustion and hot gas path inspection, rotor destacking where required, blade and vane replacement.

Add photo
(tile-3.jpg)

Steam turbine overhaul

Full-scope steam turbine overhaul and clearance recording.

Add photo
(tile-4.jpg)

Generator rewind

Generator stator / rotor withdrawal and rewind.

Add photo
(tile-5.jpg)

HRSG & boiler

HRSG / boiler pressure part work.

Add photo
(tile-6.jpg)

NDT & inspection

NDT and blade inspection close-up work.

Add photo
(tile-7.jpg)

Component refurbishment

Component repair workshop / coating booth.

Add photo
(tile-8.jpg)

Balancing & alignment

Balancing, alignment and laser work.

How an outage runs

From scope freeze to unit back on bars

An outage is won or lost before the unit comes off load. We work to a fixed sequence, with the principal’s methodology and our local execution capacity behind each stage.

01 T − 16 weeks

Scope & planning

Work scope freeze, inspection history review, long-lead parts identification, network schedule, manpower and tooling plan.

02 T − 4 weeks

Mobilisation

Visas and site NOCs, temporary import of specialist tooling, cranes and scaffolding, local manpower, accommodation and site logistics.

03 Outage window

Execution

Disassembly, NDT and clearance recording, findings review with the owner, repair or replace decisions, re-assembly under hold points.

04 Final 72 hours

Recommissioning

Alignment and balancing, protection checks, run-up, vibration signature, load trial and performance test against the pre-outage baseline.

05 T + 3 weeks

Close-out

As-found / as-left records, NCR resolution, recommendations for the next interval, spares replenishment and warranty documentation.

Sectors served

Across the whole energy sector

Thermal generation is our centre of gravity. The same engineering discipline carries into hydro, renewables and oil and gas.

Thermal & combined cycle

Gas turbines, steam turbines, generators, HRSGs, boilers, valves and balance of plant at gas-fired, oil-fired and combined cycle facilities.

Coal-fired generation

Turbine, generator, boiler and auxiliary plant maintenance and overhaul, including pressure part repair and mill and fan refurbishment.

Hydroelectric

Francis, Kaplan and Pelton turbine services, generator rewinds, governor and excitation work, and associated mechanical and electrical plant.

Solar PV

O&M for utility and C&I solar: module cleaning and IV testing, thermography, inverter service, tracker maintenance, battery storage and SCADA support — plus supply, installation and commissioning.

Wind

Scheduled and unscheduled turbine maintenance, gearbox and blade inspection, uptower repairs, drivetrain alignment and balance-of-plant electrical works.

Oil & gas

Rotating equipment at upstream, midstream and downstream facilities — compressors, gas turbines, pumps and drivers — plus turnaround support and engineering studies.

Nuclear: Conventional island and balance-of-plant engineering support only, and in each case strictly within the scope of any licence, permission or no-objection certificate required from the competent regulatory authority.

Track record in Pakistan

Work already delivered on Pakistani plant

6,900+MW of plant worked on
7OEM platforms
WorkPlantClientMWOEMScope
OverhaulGudduCPGCL120GETurbine overhaul
InspectionBQPS-IIK-Electric190HarbinGenerator repair
OverhaulEngro CCPPEngro Powergen Qadirpur245GEGenerator overhaul
OverhaulHabibullah CCPPAlbario Engineering126GE, MHIGas turbine overhaul
OverhaulHub Power CFPPInternational Power Global Dev.1,296AnsaldoTurbine overhaul
OverhaulKabirwalaFauji Kabirwala Power157WestinghouseMajor overhaul
OverhaulPak Gen CFPPPak Gen365MHITurbine & generator major overhaul
OverhaulUch-II CCPPUch-II Power404FujiInitial overhaul
CommissioningUch-II CCPPUch-II Power404FujiCommissioning technical advisory
Performance testBQPS-IK-Electric1,260Performance test
Technical advisoryKAPCOKot Addu Power1,600AlstomSteam turbine balancing
Technical advisoryLalpirLalpir Power365ParsonsGenerator inspection
Technical advisoryPak Gen CFPPPak Gen365MHILP last-stage blade replacement

Assignments executed by the international principals GES represents, on plants owned by K-Electric, KAPCO, Hubco, Engro, Fauji, Pak Gen and others.

Principals & partners

International capability, locally accountable

GES is the authorised Pakistani representative of international OEMs, independent service providers and specialist repair workshops — including providers of rotor life extension, hot gas path component repair, protective coatings and reverse-engineered replacement parts. We introduce our principals to plant owners, carry the prequalification and tendering, and take on the local execution burden so that the principal’s engineers arrive to a job that is ready to start.

Korea’s national power plant maintenance company, established 1984. Plant O&M, gas and steam turbine and generator overhaul; overseas delivery in 34 countries since 1982.

Plant operations, maintenance and performance services for thermal and combined cycle facilities.

Gas and steam turbine, HRSG and valve maintenance and overhaul.

ENG-ONE — Generator overhaul, rewind and diagnostics, with long-term service agreement delivery experience on Pakistani plant.

For international firms entering Pakistan

We absorb the local burden

Regulatory & administrative

Interface with regulators and government departments; registrations, approvals, permissions and NOCs; documentation for banking, taxation and foreign exchange.

Customs & logistics

Import and export clearance, Pakistan Single Window documentation, temporary importation of specialist tooling, freight forwarding, inland transport and warehousing.

Immigration & site access

Visa support and invitation documentation for foreign personnel, security clearances and NOCs for site access including remote and sensitive locations.

Local execution support

Manpower and technicians, consumables, scaffolding, cranes, transport, accommodation and site services in support of the principal’s scope.

Commercial & contractual

Tendering, prequalification, contract negotiation and invoicing; coordination of payment and documentation requirements.

Client engagement

Principal visits to Pakistan for technical presentations and plant surveys, and client visits to principals’ workshops abroad — with travel, interpretation and logistical support.

Why GES

Built for the new cost reality

The revised power tariff regime has placed sustained cost pressure on Pakistani IPPs and utilities, accelerating a structural shift in maintenance sourcing away from high-cost OEMs towards competitively priced, technically capable alternatives. Delivering that shift requires a Pakistani company able to bridge international technical capability and local execution. GES was constituted for exactly that purpose.

  • OEM-grade methodology and documentation, at non-OEM pricing
  • Backed by the Gohar Group’s balance sheet, banking relationships and governance
  • Industrial safety and quality assurance ahead of schedule and cost, without exception
  • One accountable contract holder in Pakistan, whatever the principal’s origin

Management policy: Top priority on industrial safety and quality assurance · cheaper energy solutions · maximisation of value for clients.

Talk to us about your next outage

Contact details to be added.

Email us